2. On the Device Configuration page, enter values for the parameters indicated in Table 2-22.
Note The question mark icon (
) in the following table shows which web page items will be defined
after the To
ggle Help button is pressed.
Table 2-22. DSR Page Device Configuration Parameters
W
eb Page Item Description
Serial Number Displays the serial number of the door strike relay.
MAC Address Displays the mac address of the door strike relay.
Version Displays the firmware version of the door strike relay.
Device Name Displays the name of the door strike relay. The default name is "LOCK,"
followed by the 9 digit ASCII serial number. The maximum name length is
13 characters. The unit will always respond to its default name.
Addressing Mode Determines whether an IP address will be manually assigned through
Static mode or dynamically assigned through a DHCP server.
IP Address Displays the IP address of the door strike relay.
Subnet Mask Displays the subnet mask of the door strike relay.
Default Gateway Displays the default gateway of the door strike relay.
Command Port This shows the port on which the door strike relay sends status packets to
the device (defaults to 49999).
Send Events When enabled, events can be sent to the associated device.
Event IP Address The IP address of the associated device.
Event Port This is the port by which the door strike relay receives commands
(defaults to 59999).
Energize Time This is the number of seconds that the relay will be energized.
DST Allows you to either enable or disable the Daylight Savings Time feature.
DST Start Sets the Daylight Savings Time starting time in the following format:
M3.2.0/02:00:00
M3 is the third month (March).
.2 is the second occurrence of the day in the month.
.0 is Sunday.
/02:00:00 is the time.
Note: When the occurrence is set to 5, the final occurrence of the day in
the specified month is used.
DST End Sets the Daylight Savings Time ending time in the following format:
M11.1.0/02:00:00
M11 is the eleventh month (November).
.1 is the first occurrence of the day in the month.
.0 is Sunday.
/02:00:00 is the time.
Note: When the occurrence is set to 5, the final occurrence of the day in
the specified month is used.