Installing the VoIP Outdoor Intercom with Keypad
Intercom Setup
Operations Guide 930809M CyberData Corporation
43
2. On the SIP page, enter values for the parameters indicated in Tabl e 2-16.
Note The question mark icon (
) in the following table shows which web page items will be defined
after the To
ggle Help button is pressed.
Table 2-16. SIP Configuration Parameters
Web Page Item Description
SIP Settings
Enable SIP Operation When enabled, the device will transmit, receive, and process SIP
messages according to the configured SIP settings below.
Register with a SIP Server When enabled, the device will attempt to register to the configured SIP
Server(s) on this page. To configure the device to send and receive point-
to-point SIP calls, enable SIP Operation and disable Register with a SIP
Server (see Section 2.4.8.1, "Point-to-Point Configuration").
Use Cisco SRST When enabled, the backup servers are handled according to Cisco SRST
(Survivable Remote Site Telephony). It is required for use in clustered
Cisco Unified Communications Manager topologies.
Primary SIP Server Enter the SIP server address as an IPv4 address in dotted decimal
notation or a fully qualified domain name. This parameter also becomes
the host portion of the SIP-URI for the device's extension on the primary
SIP server. This field can accept entries of up to 255 characters in length.
Primary SIP User ID Specify the SIP User ID for the Primary SIP Server. This parameter
becomes the user portion of the SIP-URI for the device's extension on the
primary SIP server. Enter up to 64 alphanumeric characters.
Primary SIP Auth ID Specify the Authenticate ID for the Primary SIP Server. This parameter is
required for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Primary SIP Auth Password Specify the Authenticate Password for the Primary SIP Server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Backup SIP Server 1 Enter the backup SIP server address as an IPv4 address in dotted
decimal notation or a fully qualified domain name. This parameter also
becomes the host portion of the SIP-URI for the device's extension on the
backup SIP server. This field can accept entries of up to 255 characters in
length.
Backup SIP User ID 1 Specify the SIP User ID for the first backup SIP Server. This parameter
becomes the user portion of the SIP-URI for the device's extension on the
first backup SIP server. Enter up to 64 alphanumeric characters.
Backup SIP Auth ID 1 Specify the Authenticate ID for the first backup SIP server. This parameter
is required for SIP registration authentication. Enter up to 64 alphanumeric
characters.
Backup SIP Auth Password 1 Specify the Authenticate Password for the first backup SIP server. This
parameter is required for SIP registration authentication. Enter up to 64
alphanumeric characters.
Backup SIP Server 2 Enter a second backup SIP server address as an IPv4 address in dotted
decimal notation or a fully qualified domain name. This parameter also
becomes the host portion of the SIP-URI for the device's extension on the
second backup SIP server. This field can accept entries of up to 255
characters in length.