Installing the VoIP Outdoor Intercom with Keypad
Intercom Setup
Operations Guide 930809M CyberData Corporation
51
2. On the Sensor page, enter values for the parameters indicated in Table 2-18.
Note The question mark icon (
) in the following table shows which web page items will be defined
after the To
ggle Help button is pressed.
Table 2-18. Sensor Configuration Parameters
Web Page Item Description
Door Sensor Settings
Door Sensor Normally Closed Select the inactive state of the door sensor. The door sensor is
also known as the Sense Input on the device's terminal block.
Door Open Timeout (in seconds) The time (in seconds) the device will wait before it performs an
action when the on-board door sensor is activated. The action(s)
performed are based on the configured Door Sensor Settings
below. Enter up to 5 digits.
Flash Button LED When selected, the Call button LED will flash until the on-board
door sensor is deactivated (roughly 10 times/second).
Activate Relay When selected, the device's on-board relay will be activated until
the on-board door sensor is deactivated.
Play Audio Locally When selected, the device will loop an audio file out of the
speaker until the door sensor is deactivated.
Make call to extension When selected, the device will call an extension when the on-
board door sensor is activated. Use the Dial Out Extension field
below to specify the extension the device will call.
Dial Out Extension Specify the extension the device will call when the on-board door
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio When selected, the device will call the Dial Out Extension and
play an audio file to the phone answering the SIP call
(corresponds to Door Ajar on the Audiofiles page).
Intrusion Sensor Settings
Flash Button LED When selected, the Call button LED will flash until the intrusion
sensor is deactivated (roughly 10 times/second).
Activate Relay When selected, the device's on-board relay will be activated until
the intrusion sensor is deactivated.
Play Audio Locally When selected, the device will loop an audio file out of the
speaker until the intrusion sensor is deactivated.
Make call to extension When selected, the device will call an extension when the
intrusion sensor is activated. Use the Dial Out Extension field
below to specify the extension the device will call.
Dial Out Extension Specify the extension the device will call when the intrusion
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio When selected, the device will call the Dial Out Extension and
play an audio file (corresponds to Intrusion Sensor Triggered
on the Audiofiles page) to the phone answering the SIP call