Operations Guide 930853D CyberData Corporation
Installing the VoIP Flush-Mount Indoor Intercom
Intercom Setup
36
2.4.8 Configure the Sensor Configuration Parameters
The door sensor (pins 5 and 6) on the header can be used to monitor a door's open or closed state.
There is an option on the Sensor Configuration page to trigger on an open or short condition on
these pins. The door sensor alarm will be activated when the Door Open Timeout parameter has
been met.
The intrusion sensor is an optical sensor installed on the Intercom board and will be activated when
the Intercom is removed from the case.
Each sensor can trigger up to five different actions:
Flash the LED until the sensor is deactivated (roughly 10 times/second)
Activate the relay until the sensor is deactivated
Loop an audio file out of the Intercom speaker until the sensor is deactivated
Call an extension and establish two way audio
Call an extension and play a pre-recorded audio file
Note Calling a preset extension can be set up as a point-to-point call, but currently can't send
delayed DTMF tones.