Installing the VoIP V3 Outdoor Intercom with Keypad
Intercom Setup
Operations Guide 930522C CyberData Corporation
12
2.3 Intercom Setup
2.3.1 Intercom Connections
Figure 2-3 shows the pin connections on the J3 (terminal block). This terminal block can accept
16 AWG gauge wire.
Note As an alternative to using PoE power, you can supply +12 to 24 VDC at 1000 mA (500 mA
minimum) into the terminal block.
Figure 2-3. Intercom Connections
Caution
Equipment Hazard: Contacts 1 and 2 on the J3 terminal block are only for
powering the Intercom from a non-PoE +12VDC power source as an alternative to
Network PoE power. Use of these contacts for any other purpose will damage the
Intercom and void the product warranty.
GENERAL ALERT
J3 Terminal Block
Wire (IN)
Terminal Block
can accept
16 AWG wire
Relay Contact:
(1A at 30 VDC for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
2 = Power Ground*
1 = +12 to 24 VDC at 1000 mA (500 mA minimum)*
34
Alternate Power Input:
*Contacts 1 and 2 on the J3 terminal block are only for
powering the Intercom from a non-PoE +12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
Intercom and void the product warranty.