Installing the VoIP Intercom
Intercom Setup
Operations Guide 930242AB CyberData Corporation
10
2.1 Intercom Setup
2.1.1 VoIP Intercom Connections
Figure 2-1 shows the pin connections on the J7 (terminal block). This terminal block can accept
16 AWG gauge wire.
Note As an alternative to using PoE power, you can supply 5 VDC at 1000 mA into the terminal
block.
Figure 2-1. VoIP Intercom Connections
6
5
4
3
2
1
Alt ernate Power Input :
1 = +5V at 1000 mA
2 = Power Ground
Re l ay Co n t ac t :
(2A at 30 VDC or 0.4A at 125 VAC
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
J3
Ter mi n al Block
Wire i n,
3
4
up to 16 AWG
accept wire range
for continuous loads)
(1A at 30 VDC for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
Accepts 16 AWG
gauge wire